HVAC ELECTRONICS & CONTROLS
BDQ50 Series
Single-phase compressor drive with expanded input-voltage option
The SAMYOU BDQ50 Series provides single-phase inverter control for compatible DC inverter compressors. Rated for up to 2.6 kW input power and 10 A compressor output current, it integrates sensorless FOC, SVPWM, MTPA, and field weakening. Standard, STO-equipped, and expanded input-voltage configurations support application-specific selection.
Key Features
Sensorless compressor control
Field-oriented control (FOC) with space-vector pulse-width modulation (SVPWM).
Dual closed-loop regulation
Separate speed and current loops regulate compressor operation.
Torque control
Maximum torque per ampere (MTPA) control uses the compressor motor's reluctance torque characteristics.
Extended operating range
Field weakening supports operation within the matched compressor's permitted speed range.
Controlled starting
Closed-loop starting adjusts starting torque to the load. Compressor matching is required.
Host-controller integration
Asynchronous half-duplex RS-485 communication using Modbus RTU.
Technical Specifications
| Electrical | |
|---|---|
| Input supply | 220 VAC ±20%; 208-277 VAC ±10% on BDQ50A1F5 |
| Supply phase | Single-phase |
| Input frequency | 50 / 60 Hz |
| Maximum input current | Up to 12 A at 220 VAC; variant-dependent |
| Maximum input power | Up to 2.6 kW; variant-dependent |
| Maximum compressor output current | Up to 10 A; variant-dependent |
| Output frequency | 10-120 Hz; subject to compressor specification |
| Carrier frequency | 5 kHz default |
| Full-load drive efficiency | ≥97% |
| Control & Communication | |
| Motor control | Sensorless FOC with SVPWM; dual speed and current loops |
| Torque strategy | Maximum torque per ampere (MTPA) |
| Field weakening | Supported; compressor-dependent |
| Communication | Isolated RS-485, asynchronous half-duplex; Modbus RTU |
| Mechanical & Environmental | |
| Cooling | Air cooling |
| Mechanical dimensions | See model-specific drawings |
| Operating temperature | -30 to +60 °C |
| Storage temperature | -40 to +85 °C |
| Operating humidity | 10-95% RH; no frost or condensation |
| Altitude | No derating below 1,000 m; derate by 1% per 100 m above 1,000 m; maximum 4,000 m |
Available Models
Compare configurations for your application requirements.
| Model | Configuration | Input Voltage | Key Feature | Dimensions |
|---|---|---|---|---|
| BDQ50A1F3 | Air-cooled | 220 VAC ±20% | Input: 12 A; input power: 2.6 kW; output: 10 A; Without STO | See model-specific drawing |
| BDQ50A4 | Air-cooled | 220 VAC ±20% | Input: 12 A; input power: 2.6 kW; output: 10 A; STO-equipped | See model-specific drawing |
| BDQ50A1F5 | Air-cooled; expanded voltage | 208-277 VAC ±10% | Input: 12 A; input power: 2.6 kW; output: 10 A; Without STO | See model-specific drawing |
Engineering Resources


OEM ENGINEERING SUPPORT
Need Help With Your Application?
Share your system requirements, integration needs, or product evaluation plans with SAMYOU. Our team can discuss suitable solutions for your project.